Cleaning the cell (QS500, QS2100)

To keep the electrodes working optimally, it is necessary to clean them manually at regular intervals. You can clean the electrode according to the step-by-step plan below.

Step 1:

Turn the unit off and remove the plug from the socket

Step 2:

Make sure that the system can be disconnected from the pool. For filter pump with Ø 32mm hose: Unscrew the strainers on the inside of the pool. Put the (black) plugs in the pool wall connections. For filter pump with Ø 38mm hose: Turn both knobs on the valves fully to the right to close the valves and prevent water from flowing out of the pool.

Step 3:

Loosen the nut on the plug on the electrolytic cell anticlockwise and remove the plug from the electrolytic cell

Step 4:

Loosen the nut on the electrolytic cell and remove the cell from the casing

Step 5:

Place the cell in a container. Fill the container with cleaning vinegar until the plates of the cell are submerged. Let the cell soak for at least 2 hours. In case of serious deposits, an overnight soak is recommended

Step 6:

Perform steps 3 and 4 in reverse order to place the cell back in the housing

If the problem persists, please contact local service centre for further assistance.